买道传感网

分类

商品名称: P+F 倍加福 KFU8-UFT-2.D 信号调节器 K-System (DIN rail, highly functional)

品牌名称: P+F 倍加福

分类名称: 安全传感器

商品订货号:

商品型号: KFU8-UFT-2.D

KFU8-UFT-2.D

产品参数

Electromagnetic compatibility NE 21:2006
Programming interface programming socket
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output I, II signal, relay
Response delay ≤ 200 ms
Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
Switching point/switching hysteresis logic 1: > 2.5 mA ; logic 0: < 1.9 mA
Input frequency rotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz
Open circuit voltage/short-circuit current_1 18 V / 5 mA
Input EN 60947-5-6:2000
Input I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Mutual output I, II, IV reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Display elements LEDs , display
Labeling space for labeling at the front
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Measuring range 0.001 ... 1000 Hz
Directive 2014/35/EU EN 61010-1:2010
Input III, IV/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Output III, IV/input III, IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V
Output V/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Depth 115 mm
Configuration via operating buttons via PACTware
Pulse duration min. 250 µs , overlap on direction of rotation signal: ≥ 125 µs
Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 4 mA
Resolution slip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz
Input I, II 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Output III, IV/V basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V
Interface/output III, IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V
Connection screw terminals
Power dissipation 2.2 W / 3.5 VA
Connection side control side
Mass 300 g
Height 119 mm
Width 40 mm
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Active/Passive I > 4 mA (for min. 100 ms) / I < 1.5 mA
Signal level 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA)
Open loop voltage max. 24 V DC
Interface/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Power consumption 2.5 W / 4 VA
Load max. 650 Ω
Influence of ambient temperature 0.003 %/K (30 ppm)
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Open circuit voltage/short-circuit current 8.2 V / 10 mA
Degree of protection IP20
Fault signal downscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43)
Mechanical life 5 x 10 switching cycles
Contact loading_1 40 V DC
Output III and IV signal , electronic output, passive
Output III, IV/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Signal type Digital Input
Current range 0 ... 20 mA or 4 ... 20 mA
Influence of ambient temperature_1 0.005 %/K (50 ppm)
Mutual output I, II, III reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Rated voltage U 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Output V analog
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Accuracy slip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz
Measuring time frequency measurement: < 100 ms
Rated current I approx. 130 mA
Resolution_1 < 10 µA
Accuracy_1 < 30 µA

相关资料