商品名称: P+F 倍加福 KFD2-UFT-2.D 信号调节器 K-System (DIN rail, highly functional)
品牌名称: P+F 倍加福
分类名称: 安全传感器
商品订货号:
商品型号: KFD2-UFT-2.D

产品参数
| Degree of protection | IP20 |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms |
| Open circuit voltage/short-circuit current_1 | 18 V / 5 mA |
| Collective error message | Power Rail |
| Influence of ambient temperature_1 | 0.005 %/K (50 ppm) |
| Connection side | control side |
| Display elements | LEDs , display |
| Depth | 115 mm |
| Programming interface | programming socket |
| Output I, II | signal, relay |
| Accuracy_1 | < 30 µA |
| Interface/output III, IV | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Input III, IV/power supply and collective error | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| Power consumption | 2.5 W |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Measuring range | 0.001 ... 1000 Hz |
| Line fault detection | breakage I ≤ 0.15 mA; short-circuit I > 4 mA |
| Mutual output I, II, III | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Accuracy | slip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz |
| UL approval | E223772 |
| Contact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A |
| Active/Passive | I > 4 mA (for min. 100 ms) / I < 1.5 mA |
| Contact loading_1 | 40 V DC |
| Output V | analog |
| Input frequency | rotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz |
| Output I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Connection | screw terminals |
| Rated voltage | U 20 ... 30 V DC |
| Open circuit voltage/short-circuit current | 8.2 V / 10 mA |
| Load | max. 650 Ω |
| Current range | 0 ... 20 mA or 4 ... 20 mA |
| Open loop voltage | max. 24 V DC |
| Resolution | slip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz |
| Power dissipation | 2.2 W |
| Influence of ambient temperature | 0.003 %/K (30 ppm) |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Directive 2014/35/EU | EN 61010-1:2010 |
| Switching point/switching hysteresis | logic 1: > 2.5 mA ; logic 0: < 1.9 mA |
| Input | EN 60947-5-6:2000 |
| Output III and IV | signal , electronic output, passive |
| Output III, IV/input III, IV | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Output III, IV/power supply and collective error | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Signal type | Digital Input |
| Labeling | space for labeling at the front |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Mass | 300 g |
| Height | 119 mm |
| Pulse duration | min. 250 µs , overlap on direction of rotation signal: ≥ 125 µs |
| Electromagnetic compatibility | NE 21:2006 |
| Fault signal | downscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) |
| Measuring time | frequency measurement: < 100 ms |
| Configuration | via operating buttons via PACTware |
| Mechanical life | 5 x 10 switching cycles |
| Interface/power supply and collective error | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| Input I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Mutual output I, II, IV | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Output V/power supply and collective error | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| Width | 40 mm |
| Rated current | I approx. 130 mA |
| Signal level | 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) |
| Response delay | ≤ 200 ms |
| Resolution_1 | < 10 µA |
| Input I, II | 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact |
| Output III, IV/V | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |