商品名称: P+F 倍加福 HiC2831 SIL-Capable Products for Hazardous Areas Safety Integrity Level 2

品牌名称: P+F 倍加福

分类名称: 其他

商品订货号:

商品型号: HiC2831

HiC2831

产品参数

Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Output/Output basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 V
Marking_1 II 3G Ex ec IIC T4 Gc
Output I, II signal or fault message, passive transistor output (resistive) 0-signal: 14 kΩ ± 10 % 1-signal: 1.8 kΩ ± 10 % fault: > 100 kΩ
Depth 128 mm
Maximum safe voltage_1 U 253 V AC (Attention! U is no rated voltage.)
Power P 45 mW (linear characteristic)
Systematic capability (SC) SC 3
Rated voltage U 8 V DC
Mass approx. 90 g
Mounting on termination board
Voltage U 10.5 V
Labeling space for labeling at the front
Certificate KIWA 15 ATEX 0037 X
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018 , EN 50303:2000
Ambient temperature -40 ... 70 °C (-40 ... 158 °F)
Control drawing 116-0430 (cFMus)
Power dissipation ≤ 500 mW
Connection SL1: 6b
Open circuit voltage/short-circuit current approx. 10 V DC / approx. 8 mA
Power consumption ≤ 600 mW
Coding pin 1 and 2 trimmed For further information see system description.
Dimensions 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D)
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Control elements DIP switch
Rated values acc. to EN 60947-5-6 (NAMUR), see manual for electrical data
Rated current I ≤ 25 mA
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Display elements LEDs
IECEx certificate IECEx BVS 11.0040 IECEx KIWA 15.0019X
Configuration via DIP switches
Pulse/Pause ratio min. 100 µs / min. 100 µs
EU-type examination certificate BVS 11 ATEX E 026
Connection side control side
IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I , Ex ec IIC T4 Gc
Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Input Ex ia
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Protection against electrical shock IEC 61010-1
Output type open collector transistor (internal fault bus)
Safety Integrity Level (SIL) SIL 2
Degree of protection IP20
Signal type Digital Input
Electromagnetic compatibility EN IEC 61326-3-2:2018 , NE 21:2017 For further information see system description.
Control drawing_1 116-0331
Width 12.5 mm
Ripple ≤ 10 %
Response time ≤ 200 µs
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Current I 17.1 mA
Maximum safe voltage U 253 V AC (Attention! U is no rated voltage.)
Height 106 mm
UL approval E106378
Output/power supply basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 V
Switching frequency ≤ 5 kHz