产品参数

UL approval E223772
Current range -20 ... 20 mA
Ripple within the supply tolerance
Open circuit voltage/short-circuit current 18 V / 5 mA
Output III terminals 7-, 8+, 9- non-intrinsically safe
Contact loading 253 V AC/2 A/500 VA/cos φ min. 0.7; 40 V DC/2 A resistive load
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx certificate IECEx TUN 06.0005
Temperature effect ≤ ± 0.01 %/K
Line fault detection downscale -21.5 mA (-10.75 V) or 2 mA (1 V), upscale 21.5 mA (10.75 V)
Current I 238 mA
Sensor supply 1 ... 5 V
Output I, II against eachother reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Control elements Control panel
Labeling space for labeling at the front
IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Maximum safe voltage_1 U 253 V AC / 40 V DC (Attention! U is no rated voltage.)
Short-circuit current 50 mA
Resolution/accuracy ≤ ± 0.05 % incl. non-linearity and hysteresis
Other circuits from each other functional insulation, rated insulation voltage 50 V
Rated voltage U 20 ... 35 V DC
Degree of protection IP20
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Input resistance > 1 MΩ for voltage measurement
Maximum safe voltage U_1 U 40 V DC (Attention! U is no rated voltage.)
Reaction time 300 ... 850 ms
Input II and III terminals 13+, 14-; 15+, 14- non-intrinsically safe
Electromagnetic compatibility NE 21:2006
Mass approx. 250 g
Control drawing 116-0302 (cFMus)
Width 40 mm
Maximum safe voltage U 40 V DC (Attention! U is no rated voltage.)
Power P 833 mW (linear characteristic)
Maximum safe voltage_2 U 40 V DC (Attention! U is no rated voltage.)
Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Height 119 mm
Depth 115 mm
Directive 2014/35/EU EN 61010-1:2010
Collective error message Power Rail
Analog current output 0 ... ± 20 mA or 4 ... 20 mA; load 0 ... 550 Ω (terminals 7 and 8)
Input I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Output III/Programming socket not available
Signal type Analog input
Connection side control side
Programming interface programming socket
Analog voltage output 0 ... ± 10 V; output resistance 500 Ω (bridge between terminal 7 and 9)
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
Interface RS 485 programming jack
Type RS-485
Connection_1 terminals 1+, 2-
Connection_2 terminals 3+, 4- (supply); 5+, 6- (signal)
Programmable Tare 0 ... 500 % of span
Output III/Input II, III not available
Connection screw terminals
Display elements LEDs , display
EU-type examination certificate TÜV 04 ATEX 2531
Active/Passive I > 4 mA/I < 1.5 mA
Output I, II terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Voltage U 14 V
Input signal -100 ... 100 mV
Input II, III tare adjustment, calibration and zero
Configuration via operating buttons via PACTware
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Load max. 550 Ω
Lead resistance max. 25 Ω per line
Mechanical life 2 x 10 switching cycles
Power consumption max. 3 W
Maximum safe voltage U 40 V DC (Attention! U is no rated voltage.)
Supply Power Rail or terminals 23+, 24- non-intrinsically safe
Input I terminals 1+, 2- Ex ia IIC, Ex iaD