商品名称: P+F 倍加福 KCD2-SOT-Ex1.LB SIL-Capable Products for Hazardous Areas Safety Integrity Level 2

品牌名称: P+F 倍加福

分类名称: 安全传感器

商品订货号:

商品型号: KCD2-SOT-Ex1.LB

KCD2-SOT-Ex1.LB

产品参数

Voltage U 10.5 V
Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012
Switching frequency ≤ 5 kHz
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Current I 17.1 mA
Systematic capability (SC) SC 3
Power dissipation ≤ 700 mW including maximum power dissipation in the output
Electromagnetic compatibility NE 21:2011
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Display elements LEDs
Control elements DIP switch
Maximum safe voltage_1 U 253 V AC (Attention! The rated voltage can be lower.)
Pulse/Pause ratio min. 100 µs / min. 100 µs
Output I signal ; Transistor
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Mass approx. 100 g
Labeling space for labeling at the front
Output/power supply basic insulation according to EN 50178, rated insulation voltage 50 V
IECEx certificate IECEx BAS 13.0046 IECEx CML 19.0147X
Power P 45 mW (linear characteristic)
Output II signal or fault message ; Transistor
Protection against electrical shock IEC 61010-1:2010
Rated current I 50 mA
Ambient temperature -20 ... 70 °C (-4 ... 158 °F) extended ambient temperature range up to 70 °C (158 °F) , refer to manual and derating characteristics in the datasheet for necessary mounting conditions
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Maximum safe voltage U 253 V AC (Attention! U is no rated voltage.)
Marking_1 II 3G Ex ec IIC T4 Gc
IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc
Open circuit voltage/short-circuit current approx. 10 V DC / approx. 8 mA
Input Ex ia
Ripple ≤ 10 %
Rated voltage U 30 V DC
Degree of protection IP20
Dimensions 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Control drawing 116-0374 (cULus)
Output/Output basic insulation according to EN 50178, rated insulation voltage 50 V
Certificate CML 19 ATEX 4410 X
Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Rated values acc. to EN 60947-5-6 (NAMUR)
Connection side control side
Signal level 1-signal: (external voltage) - 3 V max. for 50 mA 0-signal: blocked output (off-state current ≤ 10 µA)
Collective error message Power Rail
Configuration via DIP switches
Safety Integrity Level (SIL) SIL 2
EU-type examination certificate BASEEFA 13 ATEX 0080
Signal type Digital Input
Connection screw terminals
Response time ≤ 200 µs