商品名称: P+F 倍加福 HiC2031 SIL-Capable Products for Hazardous Areas Safety Integrity Level 2
品牌名称: P+F 倍加福
分类名称: 安全传感器
商品订货号:
商品型号: HiC2031

产品参数
| Dimensions | 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) |
| Mounting | on termination board |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-7:2015 |
| Connection side | field side |
| Input voltage | open loop voltage of the control system < 30 V |
| Display elements | LED |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Maximum safe voltage | U 250 V AC (Attention! U is no rated voltage.) |
| Power | P 630 mW |
| Internal inductance | L negligible |
| Rated voltage | U 19 ... 30 V DC bus powered via Termination Board |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
| Depth | 128 mm |
| Power consumption | ≤ 700 mW |
| Internal capacitance | C 5.7 nF |
| Mass | approx. 100 g |
| Voltage | U 25.2 V |
| Power dissipation | ≤ 600 mW at 20 mA and 500 Ω load |
| Equipment | SL2: 5a(+), 5b(-) |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Ripple | 20 mV rms |
| Output/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Labeling | space for labeling at the front |
| UL approval | E106378 |
| Rated current | I ≤ 30 mA at 24 V |
| Degree of protection | IP20 |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Output | Ex ia |
| Marking_1 | II 3G Ex ec IIC T4 Gc |
| Deviation | at 20 °C (68 °F), 4 ... 20 mA < 0.1 % of full scale, incl. non-linearity and hysteresis |
| Signal type | Analog output |
| Electromagnetic compatibility | NE 21:2017 EN 61326-3-2:2018 For further information see system description. |
| Current | I 100 mA |
| Load | 0 ... 650 Ω |
| Width | 12.5 mm |
| Rise time | 10 to 90 % ≤ 10 ms |
| FM certificate | FM 19 US 0122 X , FM 19 CA 0065 X |
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| EU-type examination certificate | CESI 06 ATEX 017 |
| Control drawing | 116-0470 (cFMus) |
| Connection | SL2: 5a(+), 5b(-) |
| Control drawing_1 | 116-0458 (cULus) |
| Voltage drop | approx. 6 V at 20 mA |
| Systematic capability (SC) | SC 3 |
| Input/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 V |
| Protection against electrical shock | UL 61010-1:2012 |
| Influence of ambient temperature | < 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) |
| Coding | pin 1 and 3 trimmed For further information see system description. |
| Input signal | 4 ... 20 mA , limited to approx. 26 mA |
| Safety Integrity Level (SIL) | SIL 2 |
| Certificate | CESI 19 ATEX 027 X |
| IECEx certificate | IECEx CES 06.0002X |
| Height | 106 mm |
| Input resistance | > 100 kΩ, with field wiring open |
| Frequency range | field side into the control side: bandwidth with 0.5 V signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 1 mA signal 0 ... 3 kHz (-3 dB) |