商品名称: P+F 倍加福 KT-MB-GT2AD.FF 高级诊断
品牌名称: P+F 倍加福
分类名称: 运动控制传感器
商品订货号:
商品型号: KT-MB-GT2AD.FF

产品参数
| Protocol | TCP/IP and UDP/IP |
| Design / Mounting | Motherboard based |
| Power dissipation | max. 2.5 W |
| Installation in hazardous area | Zone 2 / Div. 2 |
| Rated voltage | U 9 ... 35 V |
| Rated current | I 0 mA |
| Number of segments | 4 |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Galvanic isolation | IEC 62103 |
| Vibration resistance | 1 g , 10 ... 150 Hz |
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) hazardous area -40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 95 % non-condensing |
| Housing material | Polycarbonate |
| Height | see dimensions |
| Depth | see dimensions |
| Certificate | TÜV 14 ATEX 115980 X |
| Electromagnetic compatibility | NE 21 |
| Mounting | DIN rail mounting |
| Marking | II 3 G Ex nA IIC T4 Gc |
| Voltage | 50 V DC |
| Approved for | Ex nA IIC T4 Gc |
| Transfer rate | 100 MBit/s |
| Output II | alarm output diagnostic bus channel 2 , volt-free contact , NC contact |
| Output III | common alarm , volt-free contact , NC contact |
| Diagnostic Bus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| LED PWR | green: Power on |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
| Width | see dimensions |
| Climatic conditions | DIN IEC 721 |
| Ethernet/Supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| Polarity | polarity-sensitive |
| Number of Diagnostic Bus Channels | 2 |
| Fieldbus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| LED ERR | red: Hardware fault |
| Ethernet | IEEE 802.3 |
| LINK/ACT | yellow |
| Output I, II/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 250 V |
| Ethernet/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| Implementation | resource block 1x RS function block 4x MDI, 1x MDO, 1x MAI, 1x DI transducer block 16x ADM TB, 1x IO TB |
| Firmware update | Ethernet |
| Cable length/Channel | 30 m |
| Voltage_1 | 50 V DC |
| Current_2 | max. 1 A |
| Current | max. 1 A |
| Voltage_2 | 50 V DC |
| IECEx approval | IECEx TUN 14.0003X |
| Termination | integrated |
| Fieldbus standard | IEC 61158-2 |
| Mass | 470 g |
| Fieldbus type | FOUNDATION Fieldbus |
| Connection type | RJ-45 socket, 8-pin |
| Physical layer profile | profile type 114 |
| Port | 100 BASE-TX |
| CH1, CH2 | yellow: diagnostic bus activity |
| Degree of protection | IP20 |
| Shock resistance | 15 g 11 ms |
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 |
| ITK version | 6 |
| Services | ICMP , DHCP , AutoIP , HTTP |
| Number of Diagnostic Modules/Channel | 31 Using Ethernet Interface , 8 Using Fieldbus Interface |
| Current_1 | max. 1 A |
| All circuits/FE | functional insulation acc. to IEC 62103, rated insulation voltage 50 V |
| Pollution degree | max. 2, according to IEC 60664 |
| Output I | alarm output diagnostic bus channel 1 , volt-free contact , NC contact |