产品参数

Power consumption 1.4 W
Available voltage 16 V at 20 mA
Frequency range 0 ... 100 Hz
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-15:2010
Connection screw terminals
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Input/Other circuits safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V test voltage 3 kV, 50 Hz, 1 min
Output signal_1 0/4 ... 20 mA, load ≤ 300 Ω
Input signal 0/4 ... 20 mA
Influence of ambient temperature < 100 ppm/K of full-scale value
Open circuit voltage/short-circuit current ≤ 22 V / 35 mA
Protection against electrical shock EN 61010-1:2010
Dimensions 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1
Width 6.2 mm
Depth 107 mm
UL approval E106378
Connection_1 terminals 7+, 8-
Connection side control side
Output/power supply safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V test voltage 3 kV, 50 Hz, 1 min
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Rise time/fall time ≤ 3.5 ms
IECEx marking Ex nA IIC T4 Gc
Output I/II safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V test voltage 3 kV, 50 Hz, 1 min
Rated voltage U 16.8 ... 31.2 V DC
Ripple ≤ 10 mV
Power dissipation 0.8 W
Input resistance ≤ 25 Ω
Output signal 0/4 ... 20 mA, load ≤ 300 Ω
Mass approx. 70 g
Degree of protection IP20
Height 97 mm
Accuracy max. 0.1 % of full-scale value
Core cross section 0.5 ... 2.5 mm (20 ... 14 AWG)
Certificate DEMKO 16 ATEX 1750X
Marking II 3G Ex nA IIC T4 Gc
Labeling space for labeling at the front
Transmission range linearity range: -1 ... 110 %
Signal type Analog input
Operation time MTBF: 313 a acc. to SN 29500 stationary continuous operating, average ambient temperature 40 °C (104 °F)
IECEx certificate IECEx UL 16.0116X