商品名称: P+F 倍加福 KFD0-SCS-Ex1.55 SIL-Capable Products for Hazardous Areas Safety Integrity Level 2
商品型号: KFD0-SCS-EX1.55
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| Power dissipation |
150 mW at 20 mA and U < 24 V |
| Labeling |
space for labeling at the front |
| Mass |
approx. 120 g |
| Connection |
screw terminals |
| Marking_1 |
II 3G Ex nA IIC T4 Gc |
| Influence of ambient temperature |
< 0.5 µA/K |
| Height |
112 mm |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Electromagnetic compatibility |
NE 21:2007 |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Current |
I 28 mA |
| Voltage drop |
see note |
| Rise time |
≤ 20 µs at 0 Ω, ≤ 600 µs with 800 Ω load |
| Voltage |
U 23.1 V DC |
| Directive 2014/34/EU |
EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
| Load |
≤ 800 Ω (at 20 mA) |
| Width |
20 mm |
| Degree of protection |
IP20 |
| Marking |
II (2)G [Ex ib Gb] IIC |
| Depth |
115 mm |
| EU-type examination certificate |
PTB 02 ATEX 2064 |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Certificate |
PF 11 CERT 0902 X |
| Power |
P 0.647 W |
| Input/Output |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Maximum safe voltage |
U 253 V (Attention! The rated voltage can be lower.) |
| Safety Integrity Level (SIL) |
SIL 2 |
| Rated voltage |
U < 30 V DC , loop powered |
| Dimensions |
20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) (W x H x D) , housing type B2 |
| Signal type |
Analog input/analog output |
| After calibration |
≤ ± 80 µA linearity, load and voltage dependence at 20 °C (68 °F) |
| Damping |
approx. 3 dB |
|
商品名称: P+F 倍加福 P-LB-1.B.12 SIL-Capable Products for Hazardous Areas Safety Integrity Level 3
商品型号: P-LB-1.B.12
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Marking |
II (1)G [Ex ia Ga] IIC |
| Asymmetric |
100 ns |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Certificate |
PF 16 CERT 3908 X |
| Number of protected signal lines |
2 |
| Mass |
approx. 70 g |
| Dimensions |
20 x 104 x 127 mm (0.8 x 4.1 x 5 inch) (W x H x D) |
| Bandwidth |
≥ 40 kHz |
| Internal inductance |
L 200 µH |
| On-state voltage |
max. 45 V |
| Voltage |
U 30 V |
| Marking_1 |
II 3G Ex nA IIC T4 Gc |
| Rated current |
I max. 250 mA |
| Maximum leakage current |
10 kA (8/20 µs) per conductor |
| IECEx certificate |
IECEx BAS 12.0123 |
| Rated voltage |
U max. 30 V |
| Ground insulation |
max. 500 V breakdown voltage |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| Safety Integrity Level (SIL) |
SIL 3 |
| Leakage current |
max. 5 µA |
| Degree of protection |
IP20 |
| Series resistor |
≤ 0.5 Ω per wire |
| Symmetrical |
1 ns |
| IECEx marking |
[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
| Mounting |
on the KF module |
| Directive 2014/34/EU |
EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
| Connection |
terminals 1, 2 |
| Current |
I 250 mA |
| Internal capacitance |
C negligible |
| EU-type examination certificate |
PTB 02 ATEX 2044 |
|
商品名称: P+F 倍加福 HiD2822 SIL-Capable Products for Hazardous Areas Safety Integrity Level 2
商品型号: HiD2822
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Degree of protection |
IP20 |
| Mass |
approx. 140 g |
| Input/Output |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| IECEx certificate |
IECEx CES 21.0011 |
| Height |
114 mm |
| Width |
18 mm |
| Rated values |
acc. to EN 60947-5-6 (NAMUR) |
| Directive 2014/34/EU |
EN IEC 60079-0:2018 , EN 60079-11:2012 |
| Output/Output |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Labeling |
space for labeling at the front |
| Output |
signal: 2 relays SPST per channel, phase selectable |
| Maximum safe voltage |
U 250 V AC (Attention! U is no rated voltage.) |
| Pulse/Pause ratio |
min. 20 ms / min. 20 ms |
| Output/power supply |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| CSA approval |
CoC 80097459 (cCSAus) |
| Rated voltage |
U 19 ... 30 V DC bus powered via Termination Board |
| Display elements |
LEDs |
| Control elements |
DIP switch |
| Configuration |
via DIP switches |
| Input |
Ex ia |
| Switching point/switching hysteresis |
1.2 ... 2.1 mA / approx. 0.2 mA |
| Coding |
pin 1 and 2 trimmed For further information see system description. |
| Rated current |
I 45 mA at 24 V, relay energized |
| EU-type examination certificate |
CESI 21 ATEX 017 |
| Line fault detection |
breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
| Open circuit voltage/short-circuit current |
approx. 10 V DC / approx. 8 mA |
| Mounting |
on termination board |
| Switching frequency |
< 10 Hz |
| Electromagnetic compatibility |
NE 21:2017 EN 61326-3-2:2018 For further information see system description. |
| IECEx marking |
[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
| Response time |
20 ms |
| Output type |
open collector transistor (internal fault bus) |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Power dissipation |
1.1 W at 24 V |
| Mechanical life |
10 switching cycles |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Current |
I 20 mA |
| Power |
P 66 mW |
| Input/input |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 60 V |
| Factory setting |
input closed, relay energized, lead fault detection enabled |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| Connection |
SL1: 6b |
| Depth |
130 mm |
| Safety Integrity Level (SIL) |
SIL 2 |
| Dimensions |
18 x 114 x 130 mm (0.7 x 4.5 x 5.1 inch) (W x H x D) |
| Contact loading |
50 V DC / 0.5 A non-inductive |
| Input/power supply |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Marking |
II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Connection side |
control side |
| Voltage |
U 13.2 V |
| Control drawing |
116-0487 (cCSAus) |
| Signal type |
Digital Input |
| Protection against electrical shock |
UL 61010-1:2012 |
|
商品名称: P+F 倍加福 KFD2-SH-Ex1 SIL-Capable Products for Hazardous Areas Safety Integrity Level 3
商品型号: KFD2-SH-Ex1
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Input |
Ex ia |
| Input/power supply |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Power consumption |
max. 2.3 W |
| Relay de-energized |
I < 2.1 mA and I > 5.9 mA |
| Relay energized |
2.8 mA < I < 5.3 mA |
| Directive 2006/42/EC |
EN/ISO 13849-1:2015 |
| Rated current |
I ≤ 130 mA |
| Mass |
approx. 280 g |
| Connection |
screw terminals |
| Maximum safe voltage |
U 40 V AC/DC (Attention! The rated voltage can be lower.) |
| Certificate |
TÜV 99 ATEX 1493 X |
| Marking_1 |
II 3G Ex ec nC IIC T4 Gc |
| Output I |
relay , signal |
| Rated voltage |
10 ... 30 V DC |
| Degree of protection |
IP20 |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| EU-type examination certificate |
PTB 00 ATEX 2042 |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Electromagnetic compatibility |
NE 21:2017 , EN 61326-3-1:2017 |
| IECEx marking |
Ex ec nC IIC T4 Gc |
| Mutual output I, II, III |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Output/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Input/Output |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Contact loading_1 |
50 V AC/1 A/cos φ > 0.7; 24 V DC/1 A resistive load |
| Maximum safe voltage_1 |
U output I/output II: 253 V AC/DC (Attention! U is no rated voltage.) output III: 60 V AC/DC (Attention! U is no rated voltage.) |
| Power |
P 41 mW (linear characteristic) |
| Output II |
relay , signal |
| Marking |
II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Contact loading |
50 V AC/1 A/cos φ > 0.7; 24 V DC/1 A resistive load |
| Response delay |
≤ 1 ms |
| Ripple |
≤ 10 % |
| Mechanical life_1 |
50 x 10 switching cycles |
| Labeling |
space for labeling at the front |
| Current |
I 16.8 mA |
| Directive 2014/34/EU |
EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019 |
| Safety |
IEC/EN 61508:2010 |
| Dimensions |
40 x 107 x 115 mm (1.6 x 4.2 x 4.5 inch) (W x H x D) , housing type C1 |
| Voltage |
U 9.56 V |
| Signal type |
Digital Input |
| Power dissipation |
2.1 W |
| Display elements |
LEDs |
| Systematic capability (SC) |
SC 3 |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| Control drawing |
116-0158 |
| Connection side |
control side |
| Open circuit voltage/short-circuit current |
approx. 8.4 V DC / approx. 11.7 mA |
| Signal level |
1-signal: (L+) -2.5 V (7 mA, short-circuit proof) / 0-signal: blocked output (Leakage current ≤ 10 µA) |
| Performance level (PL) |
PL d |
| Safety Integrity Level (SIL) |
SIL 3 |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Mechanical life |
50 x 10 switching cycles |
| Switching frequency |
5 Hz |
| IECEx certificate |
IECEx TUN 19.0013X |
| Output III |
electronic output, passive , fault signal |
| Lead resistance |
≤ 50 Ω, in hazardous area cable capacitances and inductivities are to be taken into account |
|
商品名称: P+F 倍加福 S1SD-1AI-2U 信号调节器 SC-System (DIN rail, compact design)
商品型号: S1SD-1AI-2U
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Power consumption |
1.4 W |
| Labeling |
space for labeling at the front |
| IECEx marking |
Ex nA IIC T4 Gc |
| Output signal_1 |
0/1 ... 5 V, 0/2 ... 10 V , load ≥ 5 kΩ 0/4 ... 20 mA , load ≤ 300 Ω |
| Signal type |
Analog input |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Width |
6.2 mm |
| UL approval |
E106378 |
| Input/Other circuits |
safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V test voltage 3 kV, 50 Hz, 1 min |
| Rated voltage |
U 16.8 ... 31.2 V DC |
| Power dissipation |
0.8 W |
| Open circuit voltage/short-circuit current |
≤ 22 V / 35 mA |
| Available voltage |
16 V at 20 mA |
| Depth |
107 mm |
| Damaging gas |
designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| IECEx certificate |
IECEx UL 16.0116X |
| Connection_1 |
terminals 7+, 8- |
| Protection against electrical shock |
EN 61010-1:2010 |
| Connection side |
control side |
| Output signal |
0/1 ... 5 V, 0/2 ... 10 V , load ≥ 5 kΩ 0/4 ... 20 mA , load ≤ 300 Ω |
| Influence of ambient temperature |
< 100 ppm/K of full-scale value |
| Frequency range |
0 ... 100 Hz |
| Ripple |
≤ 10 mV |
| Output/power supply |
safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V test voltage 3 kV, 50 Hz, 1 min |
| Mass |
approx. 70 g |
| Height |
97 mm |
| Certificate |
DEMKO 16 ATEX 1750X |
| Directive 2014/34/EU |
EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
| Output I/II |
safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V test voltage 3 kV, 50 Hz, 1 min |
| Degree of protection |
IP20 |
| Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
| Dimensions |
6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1 |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Operation time |
MTBF: 272 a acc. to SN 29500 stationary continuous operating, average ambient temperature 40 °C (104 °F) |
| Accuracy |
max. 0.1 % of full-scale value |
| Storage temperature |
-40 ... 85 °C (-40 ... 185 °F) |
| Core cross section |
0.5 ... 2.5 mm (20 ... 14 AWG) |
| Marking |
II 3G Ex nA IIC T4 Gc |
| Connection |
screw terminals |
| Input signal |
0/4 ... 20 mA 0/2 ... 10 V |
| Input resistance |
≤ 25 Ω |
| Rise time/fall time |
≤ 3.5 ms |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Transmission range |
linearity range: -1 ... 110 % |
|
商品名称: P+F 倍加福 HiD2030 SIL-Capable Products for Hazardous Areas Safety Integrity Level 2
商品型号: HiD2030
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Safety Integrity Level (SIL) |
SIL 2 |
| Directive 2014/34/EU |
EN 60079-0:2018 , EN 60079-11:2012 |
| IECEx certificate |
IECEx CSAE 21.0010X |
| IECEx marking |
[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
| Width |
18 mm |
| Output/power supply |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Factory setting |
4 ... 20 mA |
| Ambient temperature |
-40 ... 60 °C (-40 ... 140 °F) |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Input/Output |
safe electrical isolation acc. to IEC 60079-11:2007, voltage peak value 375 V |
| Influence of ambient temperature |
≤ 2 µA/K |
| Height |
114 mm |
| Response time |
70 ms , 10 ... 90 % step change |
| Power |
P 605 mW |
| Coding |
pin 1 and 3 trimmed For further information see system description. |
| Deviation |
at 20 °C (68 °F), 0/4 ... 20 mA ≤ 20 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage |
| CSA approval |
CoC 80072560 (cCSAus) |
| Communication |
pass-through of HART signal to safe area The current sink terminals 4, 7 and 5, 6 do not pass HART signal to safe area. |
| Mounting |
on termination board |
| Voltage |
U 26 V |
| Signal type |
Analog input |
| Connection side |
control side |
| Connection |
SL1: 6b |
| Marking |
II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Labeling |
space for labeling at the front |
| Input/power supply |
safe electrical isolation acc. to IEC 60079-11:2007, voltage peak value 375 V |
| Input resistance |
< 40 Ω , for current source |
| Power dissipation |
800 mW at 24 V, 250 Ω load, 20 mA output (per channel) |
| Display elements |
LEDs |
| Current |
I 93 mA |
| Configuration |
via DIP switches |
| Output signal |
4 ... 20 mA or 1 ... 5 V (on 250 Ω, 0.1 % internal shunt) |
| Dimensions |
18 x 114 x 130 mm (0.7 x 4.5 x 5.1 inch) (W x H x D) |
| Electromagnetic compatibility |
NE 21:2017 EN 61326-3-2:2018 |
| Frequency range |
field side into the control side: bandwidth with 0.5 V signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 V signal 0 ... 3 kHz (-3 dB) |
| Input/input |
safe electrical isolation acc. to EN 60079-11:2007, voltage peak value 60 V |
| Relative humidity |
5 ... 90 %, non-condensing up to 35 °C (95 °F) |
| Degree of protection |
IP20 |
| EU-type examination certificate |
CSANe 21 ATEX 2149 X |
| Output/Output |
functional insulation, rated insulation voltage 50 V AC |
| Load |
0 ... 650 Ω |
| Input |
Ex ia, Ex iaD |
| Protection against electrical shock |
UL 61010-1:2012 |
| Rated voltage |
U 19 ... 30 V DC bus powered via Termination Board |
| Mass |
140 g |
| Control drawing |
116-0486 |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Control elements |
DIP switch |
| Output type |
open collector transistor (common to both channels) fault bus signal, collective error message |
| Rated current |
I 37 mA at 24 V, 250 Ω load, 20 mA output (per channel) |
| Input current |
4 ... 20 mA , current limit approx. 26 mA typ. |
| Maximum safe voltage |
U 250 V AC (Attention! U is no rated voltage.) |
| Signal level |
no fault: 1 mA ... 23.5 mA input current fault detection: < 0.2 mA or > 24 mA input current |
| Depth |
130 mm |
| Systematic capability (SC) |
SC 3 |
| Ripple |
10 mV on a load of 250 Ω |
|
商品名称: P+F 倍加福 KCD2-SCD-Ex1 SIL-Capable Products for Hazardous Areas Safety Integrity Level 2
商品型号: KCD2-SCD-Ex1
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Mass |
approx. 100 g |
| Dimensions |
12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| EU-type examination certificate |
CESI 06 ATEX 021 X |
| Voltage |
U 25.2 V |
| Electromagnetic compatibility |
NE 21:2017 EN 61326-3-2:2018 |
| Current |
I 100 mA |
| Load |
0 ... 650 Ω |
| Output/power supply |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Safety Integrity Level (SIL) |
SIL 2 |
| Connection |
screw terminals |
| Input voltage |
open loop voltage of the control system < 30 V |
| Input/Output |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Rated voltage |
U 19 ... 30 V DC |
| Certificate |
CESI 19 ATEX 021 X |
| Power |
P 630 mW |
| Display elements |
LED |
| Input signal |
4 ... 20 mA , limited to approx. 26 mA |
| Control drawing_1 |
116-0459 (cULus) |
| IECEx certificate |
IECEx CES 06.0001X |
| Influence of ambient temperature |
< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) |
| UL approval |
E106378 |
| Ripple |
20 mV |
| Input/power supply |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Deviation |
at 20 °C (68 °F), 4 ... 20 mA < 0.1 % of full scale, incl. non-linearity and hysteresis |
| Frequency range |
field side into the control side: bandwidth with 0.5 V signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 V signal 0 ... 3 kHz (-3 dB) |
| Output |
Ex ia |
| Maximum safe voltage |
U 250 V AC (Attention! U is no rated voltage.) |
| Systematic capability (SC) |
SC 3 |
| Protection against electrical shock |
UL 61010-1:2019 |
| Marking |
II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Labeling |
space for labeling at the front |
| Marking_1 |
II 3G Ex ec IIC T4 Gc |
| Height |
124 mm |
| Voltage drop |
approx. 6 V at 20 mA |
| Rated current |
I ≤ 30 mA at 24 V |
| Directive 2014/34/EU |
EN IEC 60079-0:2018 , EN 60079-11:2012 , EN IEC 60079-7:2015+A1:2018 |
| Connection side |
field side |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| IECEx marking |
[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
| Width |
12.5 mm |
| Power consumption |
≤ 700 mW |
| Equipment |
terminals 1+, 2- |
| Internal inductance |
L negligible |
| FM certificate |
FM 18 CA 0116 X , FM 19 US 0117 X |
| Ambient temperature |
-40 ... 70 °C (-40 ... 158 °F) |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Rise time |
10 to 90 % ≤ 10 ms |
| Input resistance |
> 100 kΩ, with field wiring open |
| Internal capacitance |
C 5.7 nF |
| Degree of protection |
IP20 |
| Control drawing |
116-0469 (cFMus) |
| Signal type |
Analog output |
| Power dissipation |
≤ 600 mW at 20 mA and 500 Ω load |
| Depth |
114 mm |
|
商品名称: P+F 倍加福 KCD2-SLD-Ex1.1065 SIL-Capable Products for Hazardous Areas Safety Integrity Level 3
商品型号: KCD2-SLD-EX1.1065
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Control drawing |
116-0448 (cULus) |
| Connection side |
field side |
| Input current |
80 mA at 24 V |
| Labeling |
space for labeling at the front |
| Test current |
max. 350 µA , calculated by I = 4.7 V / (15 kΩ + R ) |
| Safety Integrity Level (SIL) |
SIL 3 |
| Degree of protection |
IP20 |
| Marking |
II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Signal type |
Digital Output |
| Connection |
screw terminals |
| Energized/De-energized delay |
≤ 20 ms / ≤ 20 ms |
| Display elements |
LEDs |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Electromagnetic compatibility |
NE 21:2012 , EN 61326-3-2:2008 For further information see system description. |
| Configuration |
via DIP switches |
| Protection against electrical shock |
EN 61010-1:2010 |
| Output II/power supply |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 V |
| Connection_1 |
terminals 7, 8 , non-intrinsically safe |
| Voltage |
U 17.3 V |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Contact loading |
30 V DC/ 0.5 A resistive load |
| Mechanical life |
10 switching cycles |
| Output II |
fault signal |
| Rated voltage |
U 19 ... 30 V DC loop powered |
| Dimensions |
12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| EU-type examination certificate |
EXA 17 ATEX 0002 X |
| Current |
I 220 mA |
| IECEx certificate |
IECEx EXA 17.0001X |
| Signal level |
loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited to 5 mA) 0-signal: 0 ... 5 V DC |
| Open loop voltage |
U typ. 16.4 V |
| Control elements |
DIP switch |
| Internal resistor |
R 80 Ω |
| Directive 2014/34/EU |
EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 |
| Power dissipation |
1.3 W at 24 V |
| Maximum safe voltage |
U 60 V (Attention! The rated voltage can be lower.) |
| Systematic capability (SC) |
SC 3 |
| Output I |
Ex ia |
| Test pulse length |
max. 2 ms from DO card |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating. |
| Mass |
approx. 150 g |
| IECEx marking |
Ex nC ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I |
| Load |
nominal 0.05 ... 18 kΩ , valid range for line fault detection (LFD) |
| Rated current |
I 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) |
| Maximum safe voltage_1 |
U 60 V (Attention! The rated voltage can be lower.) |
| Maximum safe voltage_2 |
U 60 V (Attention! The rated voltage can be lower.) |
| Power |
P 947 mW |
| Current limit |
I 65 mA |
| Inrush current |
< 200 mA , 10 ms loop powered |
| UL approval |
E106378 |
| Output/other circuits |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Output I/other circuits |
safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 V |
|
商品名称: P+F 倍加福 KCD2-ST-1.LB 信号调节器 K-System (DIN rail, highly functional)
商品型号: KCD2-ST-1.LB
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Protection against electrical shock |
IEC 61010-1:2010 |
| Height |
119 mm |
| Line fault detection |
breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
| Connection |
screw terminals |
| Input/power supply |
reinforced insulation acc. to EN 50178, rated insulation voltage 300 V |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Degree of protection |
IP20 |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
| Mass |
approx. 100 g |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Configuration |
via DIP switches |
| Output/power supply |
not available , common pole terminal 9+ |
| Display elements |
LEDs |
| Depth |
114 mm |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Rated values |
acc. to EN 60947-5-6 (NAMUR) |
| Rated voltage |
U 30 V DC |
| Connection side |
control side |
| Labeling |
space for labeling at the front |
| Collective error message |
Power Rail |
| Output I |
signal ; Transistor |
| Response time |
≤ 200 µs |
| Signal type |
Digital Input |
| Width |
12.5 mm |
| Switching frequency |
≤ 5 kHz |
| Output II |
signal or fault message ; Transistor |
| Ripple |
≤ 10 % |
| Input/Output |
reinforced insulation acc. to EN 50178, rated insulation voltage 300 V |
| Safety Integrity Level (SIL) |
SIL 2 |
| Systematic capability (SC) |
SC 3 |
| Power dissipation |
≤ 700 mW including maximum power dissipation in the output |
| Output/Output |
not available , common pole terminal 9+ |
| Electromagnetic compatibility |
NE 21:2011 |
| Dimensions |
12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Signal level |
1-signal: (supply voltage) - 3 V max. for 50 mA 0-signal: blocked output (off-state current ≤ 10 µA) |
| Input |
EN 60947-5-6:2000 |
| Open circuit voltage/short-circuit current |
approx. 10 V DC / approx. 8 mA |
| Rated current |
I 50 mA |
| Switching point/switching hysteresis |
1.2 ... 2.1 mA / approx. 0.2 mA |
| Pulse/Pause ratio |
min. 100 µs / min. 100 µs |
|
商品名称: P+F 倍加福 KCD2-SR-2 信号调节器 K-System (DIN rail, highly functional)
商品型号: KCD2-SR-2
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Connection |
screw terminals |
| Output/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Width |
12.5 mm |
| Rated current |
I ≤ 46 mA |
| Output I |
signal ; relay |
| Functional safety |
IEC/EN 61508:2010 |
| Degree of protection |
IP20 |
| Mass |
approx. 100 g |
| Switching point/switching hysteresis |
1.2 ... 2.1 mA / approx. 0.2 mA |
| Systematic capability (SC) |
SC 3 |
| Power consumption |
≤ 900 mW |
| Labeling |
space for labeling at the front |
| Depth |
114 mm |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Energized/De-energized delay |
≤ 20 ms / ≤ 20 ms |
| Power dissipation |
≤ 900 mW |
| Open circuit voltage/short-circuit current |
approx. 8 V DC / approx. 8 mA |
| Input/Output |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Dimensions |
12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Line fault detection |
breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
| Signal type |
Digital Input |
| Display elements |
LEDs |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Ripple |
≤ 10 % |
| Input/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Height |
119 mm |
| Contact loading |
250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load |
| Electromagnetic compatibility |
NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018 |
| Ambient temperature |
-40 ... 70 °C (-40 ... 158 °F) |
| Input |
EN 60947-5-6:2000 |
| Pulse/Pause ratio |
min. 20 ms / min. 20 ms |
| Safety Integrity Level (SIL) |
SIL 2 |
| Switching frequency |
≤ 10 Hz |
| Directive 2014/35/EU |
EN 61010-1:2010+A1:2019+A1:2019/AC:2019 |
| Rated voltage |
U 19 ... 30 V DC |
| Connection side |
control side |
| Output/Output |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Configuration |
via DIP switches |
| Minimum switch current |
2 mA / 24 V DC |
| Mechanical life |
10 switching cycles |
| Rated values |
acc. to EN 60947-5-6 (NAMUR) |
| Output II |
signal ; relay |
|