商品名称: P+F 倍加福 KCD2-SCD-1 信号调节器 K-System (DIN rail, highly functional)
商品型号: KCD2-SCD-1
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 安全栅
|
| Ripple |
20 mV |
| Labeling |
space for labeling at the front |
| Electromagnetic compatibility |
NE 21:2017 EN 61326-3-2:2018 |
| Degree of protection |
IP20 |
| Depth |
114 mm |
| Load |
0 ... 900 Ω |
| Input/Output |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Mass |
approx. 100 g |
| Connection |
screw terminals |
| Input signal |
4 ... 20 mA , limited to approx. 26 mA |
| Deviation |
at 20 °C (68 °F), 4 ... 20 mA < 0.1 % of full scale, incl. non-linearity and hysteresis |
| Ambient temperature |
-40 ... 70 °C (-40 ... 158 °F) |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Power dissipation |
≤ 600 mW at 20 mA and 500 Ω load |
| Influence of ambient temperature |
< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) |
| Voltage |
≥ 18 V at 20 mA |
| Signal type |
Analog output |
| Rated current |
I ≤ 30 mA at 24 V |
| Current |
4 ... 20 mA |
| Safety Integrity Level (SIL) |
SIL 2 |
| Power consumption |
≤ 700 mW |
| Input/power supply |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Display elements |
LED |
| Width |
12.5 mm |
| Input voltage |
open loop voltage of the control system < 30 V |
| Rise time |
10 to 90 % ≤ 10 ms |
| Connection side |
field side |
| Input resistance |
> 100 kΩ, with field wiring open |
| Output/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Dimensions |
12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
| Voltage drop |
approx. 6 V at 20 mA |
| Rated voltage |
U 19 ... 30 V DC |
| Frequency range |
bandwidth at 0.5 V signal 0 ... 3 kHz (-3 dB) |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Height |
124 mm |
|
商品名称: P+F 倍加福 KFD0-TT-Ex1 本质安全型隔离栅 K-System (DIN rail mounting)
商品型号: KFD0-TT-Ex1
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 安全栅
|
| Rated voltage |
U 12 ... 35 V DC loop powered |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Signal type |
Analog input |
| Measuring range |
f span 4 ... 100 mV, zero point -12 ... 60 mV , both adjustable |
| Characteristic curve |
the output voltage is linearly proportionate to the input voltage (not to temperature) |
| Certificate |
TÜV 01 ATEX 1777 X |
| Directive 2014/34/EU |
EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
| Galvanic isolation |
EN 50178 |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Insulation coordination |
EN 50178 |
| Labeling |
space for labeling at the front |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| After calibration |
0.1 % of full-scale value ± 1 K for the cold junction |
| Connection |
screw terminals |
| Power dissipation |
0.4 W |
| Degree of protection |
IP20 |
| Mass |
approx. 150 g |
| Control drawing |
116-0132 |
| Load |
(U -12 V) / 0.02 A |
| EU-type examination certificate |
ZELM 00 ATEX 0035 |
| Configuration |
via DIP switches via rotary switch |
| Depth |
115 mm |
| Voltage |
U 16.1 V |
| Power |
P 3.2 mW |
| Control elements |
DIP switch rotary switch |
| Temperature effect |
temperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at T = 20 °C (68 °F)) |
| Influence of supply voltage |
6.5 ppm/V |
| Rise time |
250 ms |
| Maximum safe voltage |
U 60 V (Attention! The rated voltage can be lower.) |
| Marking |
II (1)GD [EEx ia] IIC |
| Current output |
4 ... 20 mA , limited to ≤ 35 mA |
| Width |
20 mm |
| Current |
I 0.8 mA |
| Marking_1 |
II 3G Ex nA II T4 |
| Fault signal |
downscaling ≤ 3 mA , upscaling ≥ 22 mA |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Dimensions |
20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Connection side |
control side |
| Input/Output |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Height |
119 mm |
| Lead resistance |
max. 100 Ω per line |
|
商品名称: P+F 倍加福 KCD2-ST-1.LB 信号调节器 K-System (DIN rail, highly functional)
商品型号: KCD2-ST-1.LB
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Protection against electrical shock |
IEC 61010-1:2010 |
| Height |
119 mm |
| Line fault detection |
breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
| Connection |
screw terminals |
| Input/power supply |
reinforced insulation acc. to EN 50178, rated insulation voltage 300 V |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Degree of protection |
IP20 |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
| Mass |
approx. 100 g |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Configuration |
via DIP switches |
| Output/power supply |
not available , common pole terminal 9+ |
| Display elements |
LEDs |
| Depth |
114 mm |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Rated values |
acc. to EN 60947-5-6 (NAMUR) |
| Rated voltage |
U 30 V DC |
| Connection side |
control side |
| Labeling |
space for labeling at the front |
| Collective error message |
Power Rail |
| Output I |
signal ; Transistor |
| Response time |
≤ 200 µs |
| Signal type |
Digital Input |
| Width |
12.5 mm |
| Switching frequency |
≤ 5 kHz |
| Output II |
signal or fault message ; Transistor |
| Ripple |
≤ 10 % |
| Input/Output |
reinforced insulation acc. to EN 50178, rated insulation voltage 300 V |
| Safety Integrity Level (SIL) |
SIL 2 |
| Systematic capability (SC) |
SC 3 |
| Power dissipation |
≤ 700 mW including maximum power dissipation in the output |
| Output/Output |
not available , common pole terminal 9+ |
| Electromagnetic compatibility |
NE 21:2011 |
| Dimensions |
12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Signal level |
1-signal: (supply voltage) - 3 V max. for 50 mA 0-signal: blocked output (off-state current ≤ 10 µA) |
| Input |
EN 60947-5-6:2000 |
| Open circuit voltage/short-circuit current |
approx. 10 V DC / approx. 8 mA |
| Rated current |
I 50 mA |
| Switching point/switching hysteresis |
1.2 ... 2.1 mA / approx. 0.2 mA |
| Pulse/Pause ratio |
min. 100 µs / min. 100 µs |
|
商品名称: P+F 倍加福 KCD2-SR-2 信号调节器 K-System (DIN rail, highly functional)
商品型号: KCD2-SR-2
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Connection |
screw terminals |
| Output/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Width |
12.5 mm |
| Rated current |
I ≤ 46 mA |
| Output I |
signal ; relay |
| Functional safety |
IEC/EN 61508:2010 |
| Degree of protection |
IP20 |
| Mass |
approx. 100 g |
| Switching point/switching hysteresis |
1.2 ... 2.1 mA / approx. 0.2 mA |
| Systematic capability (SC) |
SC 3 |
| Power consumption |
≤ 900 mW |
| Labeling |
space for labeling at the front |
| Depth |
114 mm |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Energized/De-energized delay |
≤ 20 ms / ≤ 20 ms |
| Power dissipation |
≤ 900 mW |
| Open circuit voltage/short-circuit current |
approx. 8 V DC / approx. 8 mA |
| Input/Output |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Dimensions |
12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Line fault detection |
breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
| Signal type |
Digital Input |
| Display elements |
LEDs |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Ripple |
≤ 10 % |
| Input/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Height |
119 mm |
| Contact loading |
250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load |
| Electromagnetic compatibility |
NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018 |
| Ambient temperature |
-40 ... 70 °C (-40 ... 158 °F) |
| Input |
EN 60947-5-6:2000 |
| Pulse/Pause ratio |
min. 20 ms / min. 20 ms |
| Safety Integrity Level (SIL) |
SIL 2 |
| Switching frequency |
≤ 10 Hz |
| Directive 2014/35/EU |
EN 61010-1:2010+A1:2019+A1:2019/AC:2019 |
| Rated voltage |
U 19 ... 30 V DC |
| Connection side |
control side |
| Output/Output |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Configuration |
via DIP switches |
| Minimum switch current |
2 mA / 24 V DC |
| Mechanical life |
10 switching cycles |
| Rated values |
acc. to EN 60947-5-6 (NAMUR) |
| Output II |
signal ; relay |
|
商品名称: P+F 倍加福 KFU8-UFT-Ex2.D 本质安全型隔离栅 K-System (DIN rail mounting)
商品型号: KFU8-UFT-EX2.D
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Current range |
0 ... 20 mA or 4 ... 20 mA |
| Load |
max. 650 Ω |
| Width |
40 mm |
| Maximum safe voltage |
U 253 V AC / 125 V DC (Attention! U is no rated voltage.) |
| Output I, II |
terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe |
| Maximum safe voltage U_2 |
U 40 V DC (Attention! U is no rated voltage.) |
| Maximum safe voltage_2 |
U 40 V (Attention! U is no rated voltage.) |
| Fault signal |
downscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) |
| Labeling |
space for labeling at the front |
| Electromagnetic compatibility |
NE 21:2006 |
| Signal type |
Digital Input |
| Input |
EN 60947-5-6:2000 |
| Measuring range |
0.001 ... 1000 Hz |
| Voltage U |
10.1 V |
| Configuration |
via operating buttons via PACTware |
| Dimensions |
40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 |
| Marking |
II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| EU-type examination certificate |
TÜV 99 ATEX 1471 |
| Pulse duration |
min. 250 µs , overlap on direction of rotation signal: ≥ 125 µs |
| Input frequency |
rotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz |
| Input I, II/other circuits |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Maximum safe voltage U |
40 V (Attention! U is no rated voltage.) |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| Control drawing |
16-538FM-12 |
| Open circuit voltage/short-circuit current |
8.2 V / 10 mA |
| Line fault detection |
breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA |
| Mutual output I, II, III |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Mutual output I, II, IV |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Output III, IV/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Display elements |
LEDs , display |
| Depth |
115 mm |
| Influence of ambient temperature |
0.003 %/K (30 ppm) |
| Response delay |
≤ 200 ms |
| Accuracy_1 |
< 30 µA |
| Input III, IV/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Power P |
34 mW (linear characteristic) |
| Degree of protection |
IP20 |
| Directive 2014/34/EU |
EN IEC 60079-0:2018 , EN 60079-11:2012 |
| IECEx marking |
[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
| Connection side |
control side |
| Power consumption |
2.5 W / 5 VA |
| Output III and IV |
terminals 19, 20, 21 non-intrinsically safe |
| Open loop voltage |
max. 24 V DC |
| Accuracy |
slip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz |
| Influence of ambient temperature_1 |
0.005 %/K (50 ppm) |
| Interface/output III, IV |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Rated voltage |
U 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz |
| Power dissipation |
2.2 W / 3.5 VA |
| Contact loading |
253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471) |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Open circuit voltage/short-circuit current_1 |
18 V / 5 mA |
| Signal level |
1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: switched off (off-state current ≤ 10 µA) |
| Resolution |
slip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz |
| Interface |
RS 232 |
| Mass |
300 g |
| Height |
119 mm |
| Mechanical life |
5 x 10 switching cycles |
| Maximum safe voltage_1 |
U 253 V (Attention! The rated voltage can be lower.) |
| Active/Passive |
I > 4 mA (for min. 100 ms) / I < 1.5 mA |
| Contact loading_1 |
40 V DC |
| Output V |
terminals 8+, 7- non-intrinsically safe |
| Output V/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Current I |
13.5 mA |
| Connection |
screw terminals |
| IECEx certificate |
IECEx TUN 04.0007 |
| Input I, II |
2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact |
| Measuring time |
frequency measurement: < 100 ms |
| Resolution_1 |
< 10 µA |
| Output I, II/other circuits |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Output III, IV/V |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Input I and II |
terminals 1+, 3-; 4+, 6-: Ex ia |
| Input III and IV |
terminals 13+, 14-; 15+, 14- non-intrinsically safe |
| Maximum safe voltage U_1 |
U 40 V (Attention! U is no rated voltage.) |
| Energized/De-energized delay |
approx. 20 ms / approx. 20 ms |
| Control elements |
Control panel |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Rated current |
I approx. 130 mA |
| Directive 2014/35/EU |
EN 61010-1:2010 |
| Programming interface |
programming socket |
| Accuracy_2 |
0.1 % |
| Output III, IV/input III, IV |
basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V |
| Interface/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
|
商品名称: P+F 倍加福 KCD2-STC-1.2O 信号调节器 K-System (DIN rail, highly functional)
商品型号: KCD2-STC-1.2O
品牌名: P+F 倍加福
分类: 模块
订货号:
类型: 信号转换模块
|
| Systematic capability (SC) |
SC 3 |
| Power consumption |
2 W |
| Influence of ambient temperature |
current output: 0.25 µA/K voltage output: 80 µV/K |
| Labeling |
space for labeling at the front |
| Connection |
screw terminals |
| Ripple |
max. 50 µA |
| Frequency range |
field side into the control side: bandwidth with 0.5 V signal 0 ... 7.5 kHz (-3 dB) control side into the field side: bandwidth with 0.5 V signal 0.3 ... 7.5 kHz (-3 dB) |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Signal type |
Analog input |
| Rated voltage |
U 19 ... 30 V DC |
| Available voltage |
terminals 1+, 2-: ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA |
| Settling time |
6 ms |
| Output/power supply |
functional insulation, rated insulation voltage 50 V AC |
| Mass |
approx. 100 g |
| Configuration |
via DIP switches |
| Output signal |
0/4 ... 20 mA or 0/1 ... 5 V |
| Input/Output |
basic insulation according to IEC 61010-1, rated insulation voltage 300 V |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Dimensions |
12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Short-circuit current |
terminals 1+, 2-: 25 mA |
| Power dissipation |
approx. 1.4 W at 20 mA transfer current, 250 Ω in both outputs |
| Display elements |
LED |
| Load |
channel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) channel 2: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) |
| Safety Integrity Level (SIL) |
SIL 2 |
| Input resistance |
terminals 1+, 2-: max. 500 Ω (BRAIN) (250 Ω load) |
| Degree of protection |
IP20 |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
| Voltage drop |
terminals 3, 4: ≤ 6.1 V at 20 mA |
| Note |
Both output loads must be connected to ensure complete and correct operation within the technical specification. |
| Input signal |
0/4 ... 20 mA |
| Deviation |
I < 20 µA (0.1 %); V < 7.5 mV (0.15 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 °C (68 °F), 0/4 ... 20 mA, 0/1 ... 5 V |
| Output/Output |
functional insulation, rated insulation voltage 50 V AC |
| Width |
12.5 mm |
| Protection against electrical shock |
UL 61010-1:2012 |
| Depth |
114 mm |
| Connection side |
control side |
| Rise time/fall time |
2 ms |
| Input/power supply |
basic insulation according to IEC 61010-1, rated insulation voltage 300 V |
| Electromagnetic compatibility |
NE 21:2012 EN 61326-3-2:2008 |
| Height |
124 mm |
|
商品名称: P+F 倍加福 HiC5861 本质安全型隔离栅 H-System (Termination Board mounting)
商品型号: HiC5861
品牌名: P+F 倍加福
分类: 继电器
订货号:
类型: 继电器
|
| UL approval |
E106378 |
| Minimum switch current |
10 mA / 24 V DC |
| Fuse rating |
1.5 A |
| Degree of protection |
IP20 |
| Dimensions |
12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) |
| Marking |
II 3G Ex nC ec IIC T4 Gc |
| Coding |
no pin trimmed For further information see system description. |
| Power dissipation |
< 1.3 W |
| Energized/De-energized delay |
150 ms / 150 ms |
| Certificate |
PF 17 CERT 4192 X |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Rated current |
I 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) |
| Output/Output |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 253 V |
| Signal level |
0-signal: -5 ... 5 V 1-signal: 19 ... 27.6 V |
| Rated voltage |
U 19 ... 27.6 V loop powered |
| Mounting |
on termination board |
| Connection side |
field side |
| Performance level (PL) |
PL e |
| Contact loading |
30 V DC/1 A resistive load |
| Electromagnetic compatibility |
NE 21:2012 , EN 61326-3-1:2008 , EN 61326-3-2:2008 |
| Mass |
approx. 100 g |
| Directive 2014/35/EU |
EN 61010-1:2010 |
| Mechanical life |
2 x 10 switching cycles |
| Test pulse length |
max. 4 ms from DO card |
| Labeling |
space for labeling at the front |
| Input/Output |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 253 V |
| Safety Integrity Level (SIL) |
SIL 3 |
| Test input |
see functional safety manual |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating. |
| Height |
106 mm |
| Width |
12.5 mm |
| Depth |
128 mm |
| Switching frequency |
< 3 Hz |
| Power consumption |
< 1.3 W |
| Connection |
SL2: 5a, 5b |
| Pulse/Pause ratio |
150 ms / 150 ms |
| Directive 2006/42/EC |
EN 62061:2005 , EN/ISO 13849-1:2008 |
| Directive 2014/34/EU |
EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-15:2010 |
| Signal type |
Digital Output |
| Display elements |
LEDs |
|
商品名称: P+F 倍加福 KFD0-CS-2.50 信号调节器 K-System (DIN rail, highly functional)
商品型号: KFD0-CS-2.50
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Mass |
approx. 100 g |
| Depth |
115 mm |
| Current |
4 ... 20 mA |
| Degree of protection |
IP20 |
| Influence of ambient temperature |
≤ ± 2 µA/K at U ≤ 20 V; ≤ ± 5 µA/K at U > 20 V |
| Input/Output |
basic insulation according to IEC 62103, rated insulation voltage 300 V |
| Rise time |
≤ 5 ms at 4 ... 20 mA and U = input voltage < 26 V |
| Signal type |
Analog input/analog output |
| Safety Integrity Level (SIL) |
SIL 2 |
| Labeling |
space for labeling at the front |
| Electromagnetic compatibility |
NE 21:2012 EN 61326-3-2:2008 |
| Transfer current |
max. 25 mA |
| Rated voltage |
U 10 ... 35 V DC , loop powered |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Power dissipation |
< 150 mW per channel at 25 mA and U < 26.1 V < 400 mW per channel at 25 mA und U > 26.1 V |
| Height |
107 mm |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
| Dimensions |
20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1 |
| Accuracy |
0.1 % |
| Connection |
screw terminals |
| Width |
20 mm |
| After calibration |
U ≥ 5 V ± 20 µA/U ≤ 5 V ± 50 µA incl. calibration, linearity, hysteresis and output load fluctuations at the field side; at 20 °C (68 °F) |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Protection against electrical shock |
EN 61010-1:2010 |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Voltage |
≥ 0.9 x U - (0.23 x current in mA) - 0.7 for 10 V < U < 26.1 V ≥ 23 V - (0.23 x current in mA) for U > 26.1 V |
| Short-circuit current |
max. 100 mA |
|
商品名称: P+F 倍加福 KFD0-CS-Ex1.54-Y2 本质安全型隔离栅 K-System (DIN rail mounting)
商品型号: KFD0-CS-Ex1.54-Y2
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 安全栅
|
| Voltage |
U 25.2 V |
| Control drawing_1 |
116-0348 (cULus) |
| Protection against electrical shock |
UL 61010-1 |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| Input/Output |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Connection |
screw terminals |
| Labeling |
space for labeling at the front |
| Height |
107 mm |
| Marking_1 |
II 3G Ex nA II T4 |
| Influence of ambient temperature |
± 20 µA / K |
| Short-circuit current |
≤ 43 mA |
| Electromagnetic compatibility |
NE 21:2006 |
| Certificate |
TÜV 99 ATEX 1499 X |
| IECEx marking |
[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex nA IIC T4 Gc |
| Signal type |
Analog input |
| Depth |
115 mm |
| Mass |
approx. 100 g |
| Dimensions |
20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1 |
| Rise time/fall time |
≤ 50 µs (load current ≥ 1 mA) |
| Rated voltage |
U 0 ... 24 V DC , loop powered |
| Marking |
II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Directive 2014/34/EU |
EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
| IECEx certificate |
IECEx BAS 08.0079 IECEx BAS 10.0007X |
| Transmission range |
current: 1 ... 20 mA voltage: 0 ... 24 V |
| Degree of protection |
IP20 |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| After calibration |
≤ 3.5 mA current loss at 20 mA load current |
| Current |
I 43 mA |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| UL approval |
E106378 |
| Width |
20 mm |
| Maximum safe voltage |
U 250 V (Attention! The rated voltage can be lower.) |
| Power dissipation |
0.2 W |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| EU-type examination certificate |
BAS 00 ATEX 7087 |
| Control drawing |
116-0129 (cFMus) |
| Power |
P 271 mW |
|
商品名称: P+F 倍加福 KFD2-ER-Ex1.W.LB 本质安全型隔离栅 K-System (DIN rail mounting)
商品型号: KFD2-ER-EX1.W.LB
品牌名: P+F 倍加福
分类: 安全传感器
订货号:
类型: 隔离栅
|
| Configuration |
via DIP switches via potentiometer |
| Electromagnetic compatibility |
NE 21:2006 |
| Mass |
approx. 150 g |
| Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Input |
[EEx ia] IIC |
| Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
| Directive 2014/35/EU |
EN 61010-1:2010 |
| Switching power |
max. 192 W , 2000 VA |
| Degree of protection |
IP20 |
| Marking |
II (1)G [EEx ia] IIC [circuit(s) in zone 0/1/2] |
| Height |
119 mm |
| Time constant for signal damping |
0.5 s, 2 s, 5 s, 10 s |
| Directive 2014/34/EU |
EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
| Output/power supply |
reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
| Output |
signal ; relay |
| Response sensitivity |
1 ... 150 kΩ , adjustable via potentiometer |
| Rated voltage |
U 20 ... 30 V DC |
| Control elements |
DIP switch potentiometer |
| Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
| Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Maximum safe voltage |
U 40 V DC (Attention! U is no rated voltage.) |
| Current |
I 2.5 mA |
| Power |
P 6 mW |
| Input/power supply |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Labeling |
space for labeling at the front |
| Signal type |
Digital Input |
| Width |
20 mm |
| Voltage |
U 10 V |
| Rated current |
I 30 ... 40 mA |
| Contact loading |
253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load |
| Dimensions |
20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Input/Output |
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| EU-type examination certificate |
DMT 00 ATEX E 033 |
| Control input |
min./max. control system: terminals 1, 2, 3 on/off control system: terminals 1, 3 |
| Connection |
screw terminals , max. 2.5 mm |
| Display elements |
LEDs |
| Connection side |
control side |
| Depth |
115 mm |
|